Recovering and Reinitializing a Standby APIC to active APIC in Cisco ACI

 Recovering and
Reinitializing a Standby APIC in Cisco ACI

If you’re working with
a standby APIC and need to verify access or promote it to an
active role, here’s a practical approach to follow.


🔐 Step 1: Accessing the Standby APIC

You can attempt to log
in using the rescue-user account. This account is specifically
designed for emergency access to standby controllers.

  • Try using your standard APIC admin
    password
     first.
  • If the standby APIC is in sync
    with the cluster
    , this should work.
  • If not, attempt login without a
    password
     — some configurations allow password-less access for
    rescue-user in isolated standby mode.


🔄 Step 2: Reinitializing the Standby APIC as
Active

If you need to promote
a standby APIC (e.g., APIC3) to an active role, it’s best to wipe and
reconfigure it from scratch
. Ensure you have KVM access to
the APIC before proceeding.

Run the following
commands in sequence:

  1. Clean the existing configuration.
  2. Trigger the setup script on next boot.
  3. Reboot the APIC to begin the reinitialization process.
These commands will:

  • acidiag touch clean
  • acidiag touch setup
  • acidiag reboot

Once rebooted, the
APIC will prompt you to configure it as part of the active cluster.


🧠 Pro Tip

Always ensure that the
APIC you’re reinitializing is physically connected to the fabric and
that you have console or KVM access. This process is irreversible and should
only be done when you’re certain the APIC is no longer needed in standby mode.

 

 Cold Standby
APIC – Key Characteristics

  • Supported in both single-pod and multi-pod ACI
    deployments.
  • Can be connected to any leaf switch in
    any pod, restoring edit capabilities in minority scenarios.
  • Automatically receives firmware
    updates to stay in sync with the active APIC cluster.
  • During upgrades, once all active APICs are
    updated, the standby APIC is upgraded automatically.
  • Assigned temporary node IDs; a new ID
    is issued when promoted to active.
  • Admin login is disabled on standby
    APICs.
  • Troubleshooting is done via SSH using
    the rescue-user account.
  • During switchover, the replaced active
    APIC is powered down to avoid dual connectivity.
  • Standby APICs do not participate in
    policy configuration or fabric management.
  • Cisco recommends placing standby APICs in
    the same pod as the active ones they may replace.
  • No configuration or credential data is
    replicated to standby APICs — only rescue-user access is
    available.